- 259
- 2 152 782
KEB America
United States
Приєднався 7 лис 2014
KEB America manufactures, assembles, and supports the North American market with German-engineered industrial automation products like controls, drives, motors, gearing, brakes, and clutches. KEB America, a subsidiary of KEB Automation KG, is located in Shakopee, Minnesota.
To learn more about KEB America, we have produced a series of videos to show how our products work, how they are made, how to install them, and how to commission them for your application.
For more information, visit our website: www.KEBamerica.com
To learn more about KEB America, we have produced a series of videos to show how our products work, how they are made, how to install them, and how to commission them for your application.
For more information, visit our website: www.KEBamerica.com
Choosing Output Filters Based on Motor Cable Length | KEB America #shorts
Is your motor drive system experiencing unexplained errors or even damage? The culprit might be hiding in plain sight: your motor cable length! Choosing the wrong output filter can lead to costly downtime and repairs.
This video breaks down KEB's recommendations for selecting the perfect filter based on cable length, covering sine-wave, dV/dt, and motor choke options. Watch now to learn how to protect your investment and optimize your system's performance!
Read the blog:
* www.kebamerica.com/blog/choosing-output-filters-based-on-motor-cable-length
Learn More about Filters:
* www.kebamerica.com/product-category/filters-chokes
-- Follow KEB America Here --
* Website: www.kebamerica.com
* LinkedIn: www.linkedin.com/company/keb-america-inc
* Facebook: KEBAmericaInc/
* Twitter: kebamerica
* Instagram: keb_america
This video breaks down KEB's recommendations for selecting the perfect filter based on cable length, covering sine-wave, dV/dt, and motor choke options. Watch now to learn how to protect your investment and optimize your system's performance!
Read the blog:
* www.kebamerica.com/blog/choosing-output-filters-based-on-motor-cable-length
Learn More about Filters:
* www.kebamerica.com/product-category/filters-chokes
-- Follow KEB America Here --
* Website: www.kebamerica.com
* LinkedIn: www.linkedin.com/company/keb-america-inc
* Facebook: KEBAmericaInc/
* Twitter: kebamerica
* Instagram: keb_america
Переглядів: 123
Відео
Driving Multiple Induction Motors with One KEB VFD | Line Feeding vs Controlling Motors with Drives
Переглядів 59914 днів тому
Automated systems frequently utilize multiple motors for load distribution, varied operations, and increased efficiency. While effective control of these motors is paramount for performance and reliability, cost-effectiveness is also a key concern. Using a single Variable Frequency Drive (VFD) to drive multiple induction motors offers a compelling solution. This article details the advantages o...
KEB America: Reflecting on 20 Years at our Shakopee, MN Facility
Переглядів 266Місяць тому
This year, we are celebrating 20 years in our Shakopee, MN facility. We sat down with Jenny Davis, Vice President of Finance at KEB America, to hear her stories about starting at KEB America in 1996 and the growth she has experienced over the years. Jenny walks us through the transition from our previous facility in Mendota Heights, MN, to the current facility we built to meet our manufacturing...
Using Ferrite Rings to Reduce EMI in VFD Applications - KEB Shorts
Переглядів 7022 місяці тому
In most troubleshooting scenarios, isolating the problem is straightforward. By carefully observing the system, forming a hypothesis, and testing that hypothesis, one can systematically address each potential cause of an issue. However, electromagnetic interference (EMI) presents a unique challenge. Unlike other issues that can be directly observed and addressed, EMI is an invisible, insidious ...
7 Steps to Reduce EMI in a VFD System - KEB Shorts
Переглядів 2302 місяці тому
When considering EMI, there is always a source, a victim, and a path. Each tip below will use grounding, shielding, or filtering methods to mitigate EMI-related issues. This video will review 7 tips to mitigate EMI-related problems in a VFD system. Read the full article: www.kebamerica.com/blog/7-steps-to-reducing-emi-with-vfds Follow KEB America * Website: www.kebamerica.com * LinkedIn: www.li...
The Advantages of using CANopen Cross-communication in KEB VFDs
Переглядів 3883 місяці тому
CAN cross enables multiple drives to exchange data directly with remarkably fast cycle rates, facilitating not only master-follower setups, but also the ability for KEB drives to manage additional tasks that would otherwise be handled by a PLC. Read the blog: * www.kebamerica.com/blog/master-follower-configuration-precision-control-with-encoder-based-vfd-synchronization Learn more about COMBIVI...
Gain Programming Experience as a Software Engineer Intern at KEB America | Don Pham's Internship
Переглядів 2884 місяці тому
Don Pham has worked diligently to gain valuable experience that strengthens his skill set, starting from his studies at @universityofminnesota to his current role as a software engineer intern at KEB America. In his journey, Don has contributed to the development of the new F6 elevator drive using C#, C , and Python programming languages for the North American market. Additionally, he has assis...
PROFINET Communication Setup | KEB Drives and Siemens PLCs using COMBIVIS 6 and TIA Portal Software
Переглядів 8125 місяців тому
This video tutorial will guide you through setting up PROFINET communication using a KEB S6 drive and a Siemens PLC. It will start with the necessary hardware and software requirements. The setup guide will then take you through the steps to configure PROFINET in KEB's COMBIVIS 6 programming software. Finally, it will guide you through connecting to the KEB device with the X6 GSDML file in Siem...
7 Tips for Long Encoder Cables in VFD Applications | KEB Shorts
Переглядів 4395 місяців тому
This video outlines 7 common ways to reduce issues that arise from long encoder cable runs. In brief, here are the tips we cover in this video: 1. Use a shorter cable (if possible) 2. Increase voltage coming from VFD 3. Add voltage at the encoder 4. Consider HTL encoders 5. Use Low resistance encoder cables 6. Use a signal repeater 7. Use Fieldbus I/O for the encoder Read the Long Encoder Cable...
What is Master-Follower and How Do You Configure KEB Drives for Multi-Axis Industrial Applications?
Переглядів 5026 місяців тому
Master-follower systems offer a powerful combination of flexibility and control, making them a game-changer for many industrial applications. This video shows you the benefits of Synchronized drives over mechanically linked applications and how this method of motor control increases flexibility, decreases the cost, and improves the load distribution of your machine's operation. Read the blog: *...
KEB America's Brake & Clutch Manufacturing Process from Start to Finish
Переглядів 1,7 тис.6 місяців тому
Learn How They're Made: A Virtual Tour Inside KEB America's Electromagnetic Brakes and Clutches Manufacturing. KEB America has become a leading brand in magnetic brakes and clutches, supplying customized solutions for robotics, self-driving vehicles (AGVs), medical devices, and even aerospace. Our entire manufacturing process, from raw materials to finished product, occurs within our state-of-t...
COMBIVIS 6 vs Studio 6 Programming Software - What's Best for Your Application? | KEB America
Переглядів 6608 місяців тому
COMBIVIS 6 vs Studio 6 Programming Software - What's Best for Your Application? | KEB America
EtherNet/IP Tutorial: Explicit Messaging in Rockwell Automation Logix 5000 Software
Переглядів 5769 місяців тому
EtherNet/IP Tutorial: Explicit Messaging in Rockwell Automation Logix 5000 Software
EtherNet/IP Tutorial: Implicit Messaging in Rockwell Automation Logix 5000 Software
Переглядів 3849 місяців тому
EtherNet/IP Tutorial: Implicit Messaging in Rockwell Automation Logix 5000 Software
EtherNet/IP Communication Tutorial | Logix 5000 Software Setup for KEB VFDs and an Allen Bradley PLC
Переглядів 28610 місяців тому
EtherNet/IP Communication Tutorial | Logix 5000 Software Setup for KEB VFDs and an Allen Bradley PLC
EtherNet/IP Communication Tutorial for COMBIVIS 6 | KEB VFD and Allen Bradley PLC Setup Guide
Переглядів 35610 місяців тому
EtherNet/IP Communication Tutorial for COMBIVIS 6 | KEB VFD and Allen Bradley PLC Setup Guide
Delivery of New Grinding Machine | KEB America
Переглядів 28010 місяців тому
Delivery of New Grinding Machine | KEB America
Startup Guide: Spin a Motor with an F6 VFD | KEB America
Переглядів 1,7 тис.11 місяців тому
Startup Guide: Spin a Motor with an F6 VFD | KEB America
Understanding VFD Input Power Monitoring | KEB Shorts
Переглядів 729Рік тому
Understanding VFD Input Power Monitoring | KEB Shorts
What An Application Engineer Does | KEB America's Elevator Support Department
Переглядів 547Рік тому
What An Application Engineer Does | KEB America's Elevator Support Department
DL4 Servo Motor - Quick Facts | UL-Certified Motors from KEB Automation
Переглядів 1,1 тис.Рік тому
DL4 Servo Motor - Quick Facts | UL-Certified Motors from KEB Automation
Purpose Built for Commercial Vehicles | KEB T6 Auxiliary Inverter
Переглядів 165Рік тому
Purpose Built for Commercial Vehicles | KEB T6 Auxiliary Inverter
What Makes a Quality VFD Motor Cable? | KEB Shorts
Переглядів 440Рік тому
What Makes a Quality VFD Motor Cable? | KEB Shorts
Harmonic Filters for the Elevator Industry | How Do They Work and What is KEB's Solution?
Переглядів 2 тис.Рік тому
Harmonic Filters for the Elevator Industry | How Do They Work and What is KEB's Solution?
How to Size a Rectifier for Your Brake or Clutch Application | KEB Automation
Переглядів 1,7 тис.Рік тому
How to Size a Rectifier for Your Brake or Clutch Application | KEB Automation
2023 National Manufacturing Day | KEB America
Переглядів 199Рік тому
2023 National Manufacturing Day | KEB America
Step-by-Step Guide to Replace a Fuse in a KEB R6 Regen Unit | KEB America Tutorial
Переглядів 812Рік тому
Step-by-Step Guide to Replace a Fuse in a KEB R6 Regen Unit | KEB America Tutorial
Why the T6 Inverter Platform is Appealing to Commercial Vehicle System Integrators | KEB America
Переглядів 259Рік тому
Why the T6 Inverter Platform is Appealing to Commercial Vehicle System Integrators | KEB America
EMI and EMC Considerations for Commercial Electric Vehicles | T6 Auxiliary Inverter - KEB Automation
Переглядів 718Рік тому
EMI and EMC Considerations for Commercial Electric Vehicles | T6 Auxiliary Inverter - KEB Automation
Why the T6 is the Most Flexible Auxiliary Inverter Platform | KEB America
Переглядів 371Рік тому
Why the T6 is the Most Flexible Auxiliary Inverter Platform | KEB America
I am trying to figure the application of this solution
How to change the motor direction in keb F5 drive Which parameter should I change please ?
I love cnc
Clear presentation. Is there are relationship between diameter/size of the ferrite ring and the current or frequency? Looks like you use a large ferrite ring; is bigger, better? Thanks.
We typically have these main considerations when we look to size a ferrite ring: 1. The wire diameter used. Typically the wire is wrapped through the ring a few times for best noise filtering so the inner diameter must be able to handle the wire gauge. 2. The frequency range that you are trying to filter out. This will be dependent on the inductance of the ring. 3. The current capacity of the ring. Each ring has a specific saturation current as which point the ferrite's peak impedance starts to reduce. This can also cause increased heating For your application, you would need to look at these factors to be sure to have the best solution. Ferrite rings are a low cost way to filter out EMC noise. Most times these help but best option is the KEB E6 EMI filter.
@@KEBAmerica Thank-you. I am installing a VFD, with output 380v, 50hz, max 10A. I do not have any noise sensitive equipment nearby, but wanted to consider EMF during my build.
How do I fix F5 drive keypad not on
Bro my F5 drive doesn’t come on. Keypad doesn’t come on as well
Thank you for your comment. It is difficult to help you diagnose the issue without more information. Please contact our technical support team for help with troubleshooting your drive. www.kebamerica.com/contact
Awesome
does this work on KEB F4 VFDs?
Can I use the s1 duty engine instead of the s3 duty engine?
Bro i have keb F5 i want to cancel encoder with vfd , how doing
This is a kind of dream Job.I would prefer to to do all my whole career.. Hobby Electronic!
Thank you ❤🙏
Congratulations on 20 years in Shakopee! Grand Projects Inc. is proud to have been a member of the KEB team assisting in your growth and success.
🎉hi I'm VFD repairing industry and keb I'm from Pakistan
Emergency power supplied by a back up generator doesn't get along with regen backfeed and may require bypass circuits with typical regen resistor bank transfer just for when running on emergency gen power.
Thanks for this series. Ntsd and ets need more focus and guidance in the industry, the spikes and faults involved to stop in time are not discussed much and best practice adjustment methods in the controller manuals are sad. Danger curve more until something blows and then dial it back 2 notches is the slightly skewed takeaway of the Motion manual.
REALLY NICE. THANKS FROM Bangladesh, I HAVE A QUESTION, WHY IN THE IGBT CIRCUIT USED INBUILT DIODE.THANKS
EtherCAT is what you want in a proper industrial network.
matrix drives
trying to create a backup from a combivert f5 but after downloading the backup to the pc from the combiwhatever f5 the parameter list is missing op61 and 62. why? i refuse to bellieve that a vfd needs 3935 paramters. why did you make it this complicated???
Thanks for your comment. After review, It could be that the software version of the parameter list is different than the drive you are connected to. Parameters are added in later versions of the software. It could be that the list you have is from an older version so op61 and 62 did not exist in that version. Without knowing more about your application and specific hardware and software versions it's difficult to give you a definitive solution, but this is a logical reason for the missing OP61 and OP62.
@ although it's an older model (f5) it has op61 and 62 because that is for forward and reverse action. when i do a complete parameter backup those two will not show up on the parameter backup list. do something with your lineup, i know I'm a nobody but i refuse to believe that a vfd needs 3950 parameters. because of this i am choosing a competitors product.
Thanks
What is the power per total weight of tubular linear motor : Kw / kg . Axial force compare to motors with core ?
Bro can More video for programming I want to programming vfd keb F5 Just Input forward and 2 speed Thank you
For décélération, it's recommended to use a braking resistor
what is the parameter offset? i searched for this word in the manual and it does not mention anything about it? why are you complicating a simple inverter this much?
Thanks for your comment. This video highlights our legacy F5 drive. In the early 2000s, this product was developed and upgraded over its 20+ years of service, improving performance and adding options with updated keypad operators. Today, we have transitioned to the F6 drive with a more simplified connection to today's technology. Let us know if you have any other questions. Thanks for watching!
are you overcomplicating your products at this level on purpose?
Thanks for your comment. This video highlights the many ways you can connect a diagnostic device such as a laptop to our legacy F5 drive. In the early 2000s, this product was developed and improved over its 20+ years of service, improving performance and adding connection options with updated keypad operators. We have now transitioned to the F6 drive with a more simplified connection to today's technology. Let us know if you have any other questions. Thanks for watching!
thanks form india
Thanks
Can Edge router publish data to AWS cloud without COMBIVIS Connect Software?
Thanks for your comment. The Edge router can publish data without COMBIVIS Connect. It is not used to publish data. However, you will need to use COMBIVIS Studio HMI to configure MQTT settings and setup tags to publish to AWS.
Thanks
i am working on F5 Ac servo drive Error show E.LSF please help me how can remove these fault . E.LSF fault are related control Card or power card please help me
Did you message or call us through our Contact Us page on our website? That is the best place to get faster answers to your questions.
Hi, I have Overload fault E.OL, but 0 A is out from driver, what can be problem ?
Did you message or call us through our Contact Us page on our website? That is the best place to get faster answers to your questions. www.kebamerica.com/contact
glad you didnt fall asleep while narrating
Thanks
How to connect only lcp keypad in pc ples tell me
Looking very professional Joe! Love to see this kind of thing in any warehouse!
if I want to monitor many PLC's from many places and each place can monitoring every PLC's , How can achieve that?
Did you message or call us about these PLC monitoring questions? Our contact page is the best place to get faster answers to your questions. www.kebamerica.com/contact
Im searching answer for only one question, If there is disengagement of clutch from power drive shaft will the driven shaft stops immediately or it will have all the inertia and go some rotations then stop, also what will be my precision i need something precise of +-5 deg. is that possible.
I encourage you to reach out to us via our Contact Us page for answers to these specific questions. Every application has its own specific requirements and our application engineers can give you the information you need. Call or email us here: www.kebamerica.com/contact
How to manually F5 Rieter drive.....???
I'm not sure what you mean. Can you explain in more detail what you are trying to achieve?
EtherCAT seems pointless now that modern ethernet switches have 4ns port-to-port latency. A switch connectes devices with only one hop instead of up to hundreds for EtherCAT.
If you have information on these claims we would be interested to see. Browsing around I can't find any switch with a port-to-port latency of 4ns. Just because a switch has low latency doesn't mean the network can actually achieve those numbers. There are a lot of factors that go into port-to-port latency. Thank you for your comment.
Hello sir. If I do not have the combivis license, can I download the plc project? the project was made with combivis 6 studio with license
I encourage you to reach out to us via our Contact Us page for specific COMBIVIS 6 questions. Call or email us here and we can send you the project file: www.kebamerica.com/contact
lot of thanks
You're welcome.
excuse me, can you share me the link of manual for 00F5060-E000 keypad and 17F5L1G-YU50 manual? Thank you
e.punch in keb drive, how to solve
I prefer 196khz switching frequency much better
Hi Firs sory to weak of my langug Why the breaking resitor be come very hot
It has to do with energy. When a VFD is using energy to turn a motor then the energy is being used for rotational motion in the motor. When a motor is turning by itself due to a load turning the motor due to gravity then energy is going from the motor back to the VFD. Energy needs to be dissipated to a braking resistor if a line regen unit is not installed. If a braking resistor gets too hot there is a possibility of components melting or even catching something on fire. This is why having the correct size braking resistor and a VFD with protection functions is essential for safe operation.
@@KEBAmerica thanks But there is meny of same machin 150 number witch works in same condition and situation just one of them is hot. I have cheked all of wireing and connections and motor but appearantly there is no problem !
What bearings do you use? How precisely can I move until bearing vibration becomes a problem?
That is a good question for Nippon Pulse. Feel free to as them about bearing wear and what would be best for your application.